The IPP-5022 is a single-ended impedance transformer that operates from 100 – 520 MHz (0.1 to .52 GHz) with a 100 Watt average power rating. The IPP-5022 transforms the impedance from 50 ohms at J1 to 12.5 ohms at J2. Its insertion loss is less than 0.50 dB. Its VSWR is less than 1.30:1.
View PDF Datasheet
View IPP Balun, SMD, 180° Transformer Application Note
Single-Ended Transformers are used to connect transmission lines of differing impedances. IPP offers single-ended impedance transformers for antenna drivers, amateur radio, commercial and military applications in frequencies ranging from 20-2500 MHz. Single-ended impedance transformers can be customized for your project.